		B600 Console - HPU Problems


	1. HPU Connector does not have any extra i/o pins available; existing
		functionality would have to change to get new i/o.
	
	2. HPU does NOT report E-Stop on pins 114 and 214.
	
	3. HPU Enable (pin B) is NOT carried through to MS-Connector on the
		pump controls.
		
	4. HPU does NOT allow remote selection of pump motors.  Should default to
		both motor start somehow or other.
	
	5. HPU does NOT allow remote reset of E-Stop condition.

	6. HPU not set for low enough supercharge pressure when bring
		both motors to high pressure.  Adjusted low supercharge
		pressure switch.

	8. Perhaps inadequate cooling for both pumps running at max flow.
		133 degrees F. for 1 pump and 1 cooling section.
		
	9. HPU does not stop on OverTemp.
	
	10. HPU will NOT start in Local unless Console E-Stop is OK
		(computer ON).
	
	11. HPU #1 has Local/Remote Lamp Burned Out.

	12. Thermostat leaks.
	