Subject: TAKENAKA
Date: Tue, 11 Jan 2000 05:11:51 -0600
From: "Imafuku, Nobuhiro" <Nobuhiro.Imafuku@mts.com>
To: "Rood, Omar" <Omar.Rood@mts.com>, "Larson, Rod" <Rod.Larson@mts.com>

Hello, OMAR and ROD san.

1.      We have a big trouble on 100 ton actuator hoses. Drawing shows
pressure port is another HSM side and return port is HSM side. But,
actually, pressure port is HSM side and return port is HSM side (Servo
valve block is under actuator position). Temporally, I use two HSM to
connect hoses (two pressure & return hoses and one pilot pressure &
return hose). But, it is impossible to connect all four hoses (- 32
pressure & return hoses). Please check hose connection drawing and reply
your comment by return.
2.      When did you send delta P cell and rest of all parts ? I check
this morning but we still do not have any invoice for this shipment.
3.      When will you send TestStar IIs software and remote control POD
?
4.      50 ton actuator installation is no trouble and system works
fine. We are waiting delta P cell to tune system now.
5.      100 ton actuator control system has a little problem.
Communication line is sometimes lost and we get error message when we
execute 469DU software. YUTAKA tells me it is something wrong at
TestStar IIs controller backplane. Probably we will have to replace
backplane in worst case.
6.      We do NOT have any ground cable for both actuators. Is this OK
for system ?

REGARDS    FUKU