Subject: FW: TAKENAKA
Date: Tue, 11 Jan 2000 07:50:41 -0600
From: "Rood, Omar" <Omar.Rood@mts.com>
To: "Petersen, Don" <Don.Petersen@mts.com>, "Smith, Jim"
     <Jim.Smith@mts.com>
CC: "Larson, Rod" <Rod.Larson@mts.com>

Don,
Panic
See Below about hoses.
Figure out what he's talking about, then lets meet.
Omar

> -----Original Message-----
> From: Imafuku, Nobuhiro
> Sent: Tuesday, January 11, 2000 5:12 AM
> To:   Rood, Omar; Larson, Rod
> Subject:      TAKENAKA
>
> Hello, OMAR and ROD san.
>
> 1.    We have a big trouble on 100 ton actuator hoses. Drawing shows
> pressure port is another HSM side and return port is HSM side. But,
> actually, pressure port is HSM side and return port is HSM side (Servo
> valve block is under actuator position). Temporally, I use two HSM to
> connect hoses (two pressure & return hoses and one pilot pressure &
> return hose). But, it is impossible to connect all four hoses (- 32
> pressure & return hoses). Please check hose connection drawing and
> reply your comment by return.
> 2.    When did you send delta P cell and rest of all parts ? I check
> this morning but we still do not have any invoice for this shipment.
> 3.    When will you send TestStar IIs software and remote control POD
> ?
> 4.    50 ton actuator installation is no trouble and system works
> fine. We are waiting delta P cell to tune system now.
> 5.    100 ton actuator control system has a little problem.
> Communication line is sometimes lost and we get error message when we
> execute 469DU software. YUTAKA tells me it is something wrong at
> TestStar IIs controller backplane. Probably we will have to replace
> backplane in worst case.
> 6.    We do NOT have any ground cable for both actuators. Is this OK
> for system ?
>
> REGARDS    FUKU
>