Subject: RE: TAKENAKA
Date: Tue, 11 Jan 2000 09:30:54 -0600
From: "Rood, Omar" <Omar.Rood@mts.com>
To: "Imafuku, Nobuhiro" <Nobuhiro.Imafuku@mts.com>, "Larson, Rod"
     <Rod.Larson@mts.com>, "Ito, Masayuki" <Masayuki.Ito@mts.com>
CC: "Petersen, Don" <Don.Petersen@mts.com>, "Smith, Jim"
     <Jim.Smith@mts.com>, "Otsuka, Yutaka" <Yutaka.Otsuka@mts.com>

Hello Fuku,

I tried call yur house and also your mobile at 10 pm your time, no
answer?

1.  A.  Sorry about the big trouble with the hoses.
     B.  I will have Don Petersen order and ship new hoses but we can
not get the hoses to Takenaka in time for their first tests, it would
take almost 1 month to get new hoses made and shipped to Takenaka.
      C.I think you can make the existing hoses work if you have 2 each
2 inch return hoses to extend the return hose lengths.  Is that correct?
 Dohnen has many 2 inch hoses with connectors.  Ito-san will know if Dr.
Horikiri would let us use 2 of his hoses for one month.

2.  The delta p cells (with parts) left here 6 January for 2 day
shipment to you at MTS-J.  They arrived DHL Japan facility Tuesday, Jan
11, but were sent to the wrong facility, as of 06:27 11 January, they
were sent to the correct facility.  Airway bill number is 9105938343.
My guess is you will have the parts tomorrow.

3.  A.  Rod is working on getting the structural software.  You do know
that the standard software had a problem.  I have heard that the
software problem has been corrected, but I do not know if the new
software is available for shipment yet.
    B.  There is no remote control Pod (?, I think you mean remote
control station?)  in the BOM.     These are expensive, many, in fact
most, structural shipments do not have those, why is it now included in
the Takenaka job?

4.  N/A

5.  I will ask Rod to answer.  I understood that the controller had no
problem when here at MTS.  I would be surprised if we had to replace the
backplane.

6.  Rod says no ground is usually not a problem.  I did have a problem
in Dalian, it turned out the console wiring ground was not good so there
was a voltage difference of 50 volts beween the console ground and the
actuator.  Personally, I prefer to always have an actuator  ground.  It
is cheapest if you just buy wire and connecting lugs in Japan and
install the grounds.

Regards
Omar

> -----Original Message-----
> From: Imafuku, Nobuhiro
> Sent: Tuesday, January 11, 2000 5:12 AM
> To:   Rood, Omar; Larson, Rod
> Subject:      TAKENAKA
>
>     Hello, OMAR and ROD san.
>
> 1.    We have a big trouble on 100 ton actuator hoses. Drawing shows
> pressure port is another HSM side and return port is HSM side. But,
> actually, pressure port is HSM side and return port is HSM side (Servo
> valve block is under actuator position). Temporally, I use two HSM to
> connect hoses (two pressure & return hoses and one pilot pressure &
> return hose). But, it is impossible to connect all four hoses (- 32
> pressure & return hoses). Please check hose connection drawing and
> reply your comment by return.
> 2.    When did you send delta P cell and rest of all parts ? I check
> this morning but we still do not have any invoice for this shipment.
> 3.    When will you send TestStar IIs software and remote control POD
> ?
> 4.    50 ton actuator installation is no trouble and system works
> fine. We are waiting delta P cell to tune system now.
> 5.    100 ton actuator control system has a little problem.
> Communication line is sometimes lost and we get error message when we
> execute 469DU software. YUTAKA tells me it is something wrong at
> TestStar IIs controller backplane. Probably we will have to replace
> backplane in worst case.
> 6.    We do NOT have any ground cable for both actuators. Is this OK
> for system ?
>
> REGARDS    FUKU
>