What we have from MTS: (I am assuming that we will have to get connectors for the equipment too as well as mating connectors (to MTS cables). 1. 2 standard moog valve cables - 57193711 1 dual valve/actuator cable - 57255511 these cables need a 2 port Y or 3 port Y cable adapter to go to the Rexroth servovalve. We need a connector to +/- 24 Volts to run the valve and a connector to the MS cable coming from controller to provide the command voltage (not current). Optionally, we can have the valve feedback coming back to the controller to an A/D channel on a 3rd connector. Does the FT40 have a BNC connector for analog inputs or do we have to go to the RJ50 for the A/D ? can we get the mating connector for the valve MS connector in Pavia ? I think you did this for the DTS2500 right ? 3. We need 3 adapter cables from the Load Cell cable (57099211) to the pressure transducers. Again, we will need the mating MS connector for the MTS cable. 4. We need to make 3 new cables to bring the 3 actuator displacement pots to the 494 DUC(s), OR, we might be able to use the 2 LVDT cables cuz they are similar to the load cell cables really... and we might be able to use the decoder cable as the 3rd one.... in that case, we only make 2 of one adapter and 1 for the decoder cable and we don't need any RJ-50 stuff at all....